Press and hold the UP button for more than 12 seconds to view the cause of the last trip (e.g., over-voltage or over-current).

: Because it resets automatically, always investigate and remove the faulty load if the device trips frequently to prevent heat buildup in your wiring. tomzn tovpd160ec manual better

To enter the setting mode, . Use the UP and DOWN keys to adjust values, then hold SET for 3 seconds again to save and exit. Default Value Adjustable Range A1 Power-on delay (reconnect time) 1s – 500s A2 Over-voltage protection value 230V – 300V (or OFF) A3 Over-voltage recovery value 225V – 295V A4 Recovery delay time (after over-voltage) 1s – 500s A5 Over-voltage protection action time 0.1s – 30s A6 Under-voltage protection value 140V – 210V (or OFF) A7 Under-voltage recovery value 145V – 215V A8 Recovery delay time (after under-voltage) 1s – 500s A9 Under-voltage protection action time 0.1s – 30s A10 Over-current protection value 1A – 63A A11 Recovery delay time (after over-current) 1s – 500s A12 Over-current protection action time 0.1s – 30s A13 Voltage calibration -9.5V to +9.5V A14 Over-current limit cycles (auto-lock) 1 – 20 times Operational Shortcuts & Indicators Press and hold the UP button for more

If you’re in a rush, the core settings are standard for most digital timers, so let me give you a better explanation than the original manual. Use the UP and DOWN keys to adjust